Data Center Cooling Equipment Maintenance & Repairs
Safeguard your IT environment, extend system lifespan, and avoid costly downtime with preventative maintenance on data center cooling equipment, such as the DX-P and MEWALL.
Protect Your Data Center Cooling Infrastructure
The key to efficient and reliable data center cooling is routine system maintenance. Mitsubishi Electric’s multi-faceted cooling system services proactively identify issues and establish parts replacement schedules to mitigate repair.
With the equipment OEM as your service provider, preventative maintenance becomes predictive – we’ll help you know what updates and upgrades are coming so you can proactively plan and implement them.
Our Field Service Technicians have specialized experience with mission-critical environments and employ industry-leading training and tools to maintain, troubleshoot, and repair your data center cooling units.
Ready to protect your investment?
Annual Data Center Cooling System Maintenance
At a minimum, your DX-P or MEWALL thermal wall system should be serviced annually. Mitsubishi Electric’s comprehensive annual data center cooling equipment maintenance plans include physical, refrigerant and electrical inspections, as well as adjustments and recommendations for action where necessary.
- Alarm & Safety Checks: Active and historical alarm review and voltage verification
- Thorough Cleaning: Remove any dust and/or debris on internal and external components, especially the evaporator and condenser coils per factory guidelines.
- Leak Detection: Scan for refrigerant leaks and verify any findings.
- Fan & Mechanical Inspections: Inspect condenser and evaporator fans for free rotation, tighten all electrical and mechanical connections to factory specifications, and verify wiring per diagrams.
- VFD, Compressor & Electrical Systems: Inspect VFD (Variable Frequency Drives), compressors, and electrical cabinets, contactors, fuses, and wiring
- Drain & Coil Maintenance: Inspect and vacuum drain lines and pans, prime P-traps, filters and coil fins
- Sensor Calibration: Calibrate and insulate temperature and pressure sensors
- Full Operational Test & Final Quality Check: Comprehensive system test under full load to ensure the system is operating per factory standards.

Quarterly Data Center Cooling System Maintenance
While annual service is essential, quarterly maintenance is recommended for optimal system performance. Quarterly DX-P and MEWALL preventative maintenance includes:
- Alarm & Safety Checks
- Thorough Cleaning & Inspection
- Fan & Compressor Service
- Electrical System Check
- Coil & Filter Maintenance
- Operational Testing & Final Quality Check
With quarterly maintenance, you benefit from earlier detection of performance drift or wear, further protecting your data center cooling infrastructure.
After both annual and quarterly maintenance visits, our Service team will quickly follow-up with comprehensive documentation of findings, required system repairs, and adjustments or remedial action plans when necessary.
Frequently Asked Questions
CritiCool® Service Contract Plans
Don’t Let Your Business Go Dark® with Mitsubishi Electric’s flexible Service Contract Plans!
Our contract plans offer exclusive advantages, such as discounts on parts and priority response times during critical emergencies. Avoid unplanned capital expenses with planned service costs.
Service Contract Customers Save an Estimated 27-38%!*
Gold, Silver, and Bronze contracts available.
*Savings are based on a service contract plan compared to a pay-as-you-go approach over 5 years for a 40 kW DX-P. Costs include preventative maintenance, replacement of lifecycle parts, and unlikely remedial repairs.
Contact Us
For all service-related inquiries, please fill out the form below. For 24/7 technical support, please call 1-800-887-7830, option 1. By submitting this contact form, you agree that a representative(s) of Mitsubishi Electric Power Products, Inc. (MEPPI) may contact you using the information you provided. In accordance with our Privacy Policy, we will never share or sell your personal data.