UPS Maintenance and Repairs
UPS preventative maintenance ensures your system runs smoothly and UPS repairs are mitigated, if not proactively identified. Mitsubishi Electric delivers top notch UPS system services to ensure that your business doesn’t go dark.
Enhance Reliability and Equipment Life with UPS Maintenance
The key to an efficient and reliable UPS is diligent routine maintenance and timely lifecycle parts replacements.
With Mitsubishi Electric, UPS preventative maintenance becomes predictive: proactively identifying and neutralizing potential threats while letting you know what updates and upgrades are coming down the line.
Our Field Service Technicians employ industry-leading training, tools, and expertise to maintain, troubleshoot, diagnose, and repair. Contact us, and we will work with you to establish your ideal UPS maintenance plan.
Annual Uninterruptible Power Supply Maintenance
It’s important to schedule annual UPS system service to ensure that your UPS is running smoothly and reduce your need for UPS parts replacements. Mitsubishi Electric offers annual UPS maintenance as part of our standard contracts, and they include physical and electric inspections, as well as adjustments or recommendations for action.
- Visual inspection of internal components and wiring for loose connections, deterioration or damage – anything that could impact proper operation
- Verification of proper software, control power devices, converter/rectifier operation, inverter operation, and cooling fan operation.
- Test of static/internal maintenance bypass operation and system voltages and currents.
- Verification of transfer operations and emergency (backup) mode operation and emergency power off (EPO test).
- Verification that UPS is supporting the critical load.
With annual UPS preventative maintenance, we’ll provide a fast follow through with comprehensive documentation of findings, required UPS repairs, and adjustments or remedial action plans when necessary.


Quarterly / Semi-Annual UPS Maintenance
While annual service is the suggested minimum, we recommend our technicians come out and perform UPS system service at least twice a year to ensure your system is functioning properly. There may also be value in quarterly inspections, especially as your equipment ages. Quarterly/semi-annual UPS preventative maintenance includes:
- Physical environment inspection for any elements that could impact operation.
- Verification of proper software versions and adjustable parameters
- Verifications of proper cooling fan operation and display of system values
- Review of event or fault history
- Verification UPS is supporting the critical load and no alerts/alarms are present
As with annual UPS preventative maintenance, we’ll generate a test report and discuss any necessary UPS repair service while we’re onsite.
Check out detailed information about our uninterruptible power supply maintenance checklist!
EverPowerTM Service Contract Plans
We make UPS maintenance easy and ensure that your business doesn’t go dark. By choosing an EverPower™ Service Contract Plan, you receive a wide range of benefits and services delivered by our experienced and knowledgeable technicians. Our contract plans offer exclusive advantages such as discounts on parts and priority response times during critical emergencies. EverPower™ contract customers save an estimated 42-51%! Gold, Silver, and Bronze level contracts are available.
Contact Us
For all service-related inquiries, please fill out the form below. For 24/7 UPS system technical support, please call 1-800-887-7830, option 1. By submitting this contact form, you agree that a representative(s) of Mitsubishi Electric Power Products, Inc. (MEPPI) may contact you using the information you provided. In accordance with our Privacy Policy, we will never share or sell your personal data.