Product Lifecycle Support

Mitsubishi Electric is committed to delivering superior service and support over the operating life of all of our UPS equipment.

As technologies mature and components become obsolete, it ultimately becomes challenging and then no longer feasible to provide replacement parts, services, and support for legacy products.

 

As we continue to develop and introduce new technologies, customers will have the opportunity to update their critical power infrastructure and keep pace with higher uptime and efficiency expectations, increased loads, new connectivity options, and tighter security requirements.

 

However, we understand that a critical power upgrade or replacement needs to be a carefully planned event.

 

Below, we have published our Product Lifecycle Support Phases and Schedule – and provided a document request form for legacy products – so that customers can make well-informed decisions regarding the maintenance, updating, and upgrading of their Uninterruptible Power Supplies (UPS) and associated peripherals.

 

We also have listed potential UPS replacement models for equipment that has passed the Active Support phase.

Four overlapping arrows labeled active support, sustained support, obsolete, and best effort support.

Arrow forming a circle, pointing clockwise.

Active Support

Full technical support and all replacement parts are available. Product is currently in production and available as new.

 

Uninterruptible Power Supplies

 

Model  
9900D  SUMMIT Series® 
9900CX 1100A
9900C 1100B
9900B 7011B
9900AEGIS  9950

 

Batteries

 

Chemistry Manufacturer Model / Part Number
Lithium-ion Samsung BCL04-CB
BCL04-CBA01
VRLA

Deka East Penn

High Rate Front & Top Terminal Batteries

HR3500; HR3500ET
HR5500; HR5500ET
HR7500; HR7500ET

EnerSys Data Safe

Top Terminal Batteries

NPX-35TFR; NPX-80RFR; NPX-100RFR
12HX35-FR; 12HX50-FR; 12HX80-FR; 12HX100-FR; 12HX150-FR; 12HX205-FR; 12HX300-FR; 12HX330-FR; 12HX400-FR; 12HX505-FR; 12HX540-FR
Pure Lead

C&D Technologies

Front & Top Terminal Batteries

UPS12-155PLP
UPS12-215PLP
UPS12-305PLM
UPS12-355PLM
UPS12-405PLM
UPS12-495PLM
UPS12-545PLM
UPS12-605PLM
UPS12-675PLMF
UPS12-705PLMF
UPS12-1005PLMF

EnerSys Data

Safe XE Front & Top Terminal Batteries

12XE760-FR
12XE1040-FR
12XE1010F-FR
12XE1110F-FR
12XE1150F-FR

 

Battery Cabinets

 

Part Number Manufacturer
BC7 C&C Power
BC11
BC16
BC34
BC43
BC55
UBC65
UBC80
UBC87
BCM04 Mitsubishi Electric Power Products, Inc. (MEPPI)

 

DC Disconnect Products

 

Part Number Manufacturer
DCDW C&C Power
DCDF
DCLF

 

IT Cooling Systems

 

Model
DX-P
MEWALL

 

Technical documentation for systems under Active Support can be found here or on each individual product page.    

 

 

Yellow arrow forms a circular loop.

Sustained Support

Full technical support and all replacement parts are expected to be available until the announced end of support date.

 

Uninterruptible Power Supplies

 

Model  End of Support Date  Potential Replacement* 
7011A 01/2027 7011B
9700 (100, 150, 225 kVA) 09/2027 Contact Us

 

Batteries

 

Chemistry Manufacturer Part Number
Lithium-ion Samsung BCL04-BB
BCL04-BBA01

 

 

Two-toned circular arrow forming a closed loop.

Best Effort Support

Limited technical support, field services, and replacement parts are available until the announced end of support date.

 

Uninterruptible Power Supplies

 

Model End of Support Date Potential Replacement*
9900A 12/2026 (Projected) 9900AEGIS
9800A-E 03/2027 9900AEGIS; 9900B

 

Batteries

 

Chemistry Manufacturer Part Number
Lithium-ion SAFT BCL06
BCL07

 

 

Arrow spiraling clockwise, forming a circular design.

Obsolete

Announced end of support date has passed. Technical support and replacement parts are no longer available.

 

Uninterruptible Power Supplies

 

Model Potential Replacement*
8600 9900AEGIS; 9900B
8700 1100 Series; Derated 9900AEGIS
2033AB (Analog) 1100 Series
2033C (30-50kVA) 1100 Series
2033C (10-20kVA) 1100 Series
>2033G 1100 Series
2033D 1100 Series with transformers; 9900AEGIS
2033A-D 1100 Series
2033A-E 1100 Series
9100 Contact Us
9700 (300-375kVA) Contact Us
9800A-A 9900AEGIS; 9900B
9800A-B 9900AEGIS; 9900B
9800A-C 9900AEGIS; 9900B
9800A-D 9900AEGIS; 9900B

 

Request technical documents for legacy products!

 

*All suggested UPS replacement options serve as a general starting point. Please contact us with replacement inquiries.

 

Batteries

 

Chemistry Manufacturer Part Number
VRLA

C&D Technologies

High Rate MR Batteries

UPS12-150MR
UPS12-210MR
UPS12-300MR
UPS12-350MR
UPS12-490MR
UPS12-540MR

 

Battery Cabinets

 

Part Number Manufacturer
UBC64 C&C Power

Next Steps for Your UPS System

As your system ages and reaches around 75% of its expected service life (roughly 10-12-year mark), it becomes increasingly important to start planning to either replace UPS lifecycle parts or do a full UPS replacement.

 


Legacy Product Documentation Request

For technical documentation for products at or below Sustained Support, please fill out the below form.

Available documents will be emailed to you.

By submitting this contact form, you agree that a representative(s) of Mitsubishi Electric Power Products, Inc. (MEPPI) may contact you using the information you provided. In accordance with our Privacy Policy, we will never share or sell your personal data.    

 

 


Have further questions?